Pages

Monday, 20 March 2017

junos system alarms "autorecovery information needs to be saved", rescue configuration is not set

Typical alarms after deploying a JunOS based Juniper SRX router that can be simple to resolve.

2 alarms currently active
Alarm time               Class  Description
2017-01-18 23:13:16 CST  Minor  Autorecovery information needs to be saved

2017-01-18 23:13:13 CST  Minor  Rescue configuration is not set


AlarmAutorecovery information needs to be saved

"request system autorecovery state save"

Alarm: Rescue configuration is not set
"request system configuration rescue save"